ELS-3K6-PSU-V1
3600W Power Supply and Power Distribution Unit
GENERAL INFORMATION
The 3600W Power Supply and Power Distribution Unit is capable of operating with both AC and DC voltage. In case of power failure in the AC supply line, the unit automatically and uninterruptedly switches to the DC supply line. It produces multiple DC power at different voltage and current levels from AC or DC source. It can communicate by RS422 Communication Infrastructure with the units connected to the unit that have this infrastructure. It meets the military standard MIL-STD-461 requirements for electromagnetic compatibility (EMC). Thanks to its environmental conditions and EMC properties, it can be easily used in needs in the communication, consumer, green energy, industrial, medical, power management and transportation sectors, as well as aviation/defense applications.
TECHNICAL SPECIFICATIONS
Input Features
AC Input Voltage Range |
100-265Vac (Nominal 220Vac, Phase- Neutral) |
Input Frequency Range |
47-63Hz |
Efficiency at Full Load |
>92% at Nominal Input |
Power Factor at Full Load |
>95% (typically %99) |
Current Total Harmonic Distortion |
less than 5% |
Instantaneous Input Current Opening Value |
<50A Except the First 10 ms |
Leakage Current Value to the Body |
<30mA |
DC Input Voltage Range |
20-30 Vdc (Nominal 24Vdc) |
Input Isolation |
DC Input Isolated from Chasis |
Output Failures
Output Voltage (nom.) |
28±0,2 Vdc |
| 36±0,2 Vdc | |
| 12±0,2 Vdc | |
| 24±0,2 Vdc | |
| 5±0,2 Vdc | |
Output Current (max.) |
20±2 A |
Output Power (nom.) |
3600W |
Environmental Features
Operating Temperature |
-0ºC ~ +55ºC |
Storage Temperature |
-40ºC~ +70ºC |
Humidity |
95% relative humidity at +40ºC |
Mechanical Features
Dimensions |
Width: 482±1 mm, |
| Height: 43±1 mm (1U), | |
| Depth: 575±1 mm | |
Cooling |
Built-in Axial Fan |
Weight |
13±0,2 kg |
Other |
|
|
|
Mountable to 19” rack cabinet |
|
|
Two carrying hadle in the rear panel |
|
|
Easy cleanable filter |
Compliances to Standards
Compliances to Standards |
MIL-STD-810D-G: Environmental Conditions Compliance |
| MIL-STD-461G: Electromagnetic Compliance | |
| MIL-STD-1275B: Electrical Compliance for Military Grade Vehicles | |
| MIL-STD-1399 300B: Military Grade Alternative Current Compliance | |
| MIL-STD-1472F | |
| MIL-STD-461D (gemi ve denizaltı) | |
| CE101, CE102, RE101, RE102, RS101, RS103, CS114, CS116 |
Other Features
Other Features |
Automatically switch to DC line in case of AC power failure |
| RS422 communication infrastructure | |
| 2000 W output power option | |
| MTBF :15000 hours | |
| MTTR <30 min. | |
| Life time 40000 hours (min.) |