ELS-2K0-PSU-V1
2000W AC/DC POWER SUPPLY and POWER DISTRIBUTION UNIT
GENERAL INFORMATION
The 2000W Power Supply and Power Distribution Unit is capable of operating with
both AC and DC voltage.
In case of power failure in the AC input line, the unit automatically and mains
provides a seamless transition to the DC input line.
It generates Multiple DC power at different voltage and current levels from AC or DC source.
With the RS422 Communication Infrastructure, it can communicate with the units
connected to the unit and having this infrastructure.
TECHNICAL FEATURES
Input Features
AC Input Voltage Range | 100-265Vac (Nominal 220Vac, Phase-Neutral) |
Input Frequency Range | 47-63Hz |
Efficiency at Full Load | >92 at Nominal Input |
Power Factor at Full Load | >95%(typically %99) |
Current Total Harmonic Distortion | <%5 |
Instantaneous Input Current Opening Value | <50A except for the first 10ms |
Leakage Current Value to the Body | <30mA |
DC Input Voltage Range | 20-30 Vdc (Nominal 24Vdc) |
Input Isolation | DC input line is isolated from chasis |
Output Features
Output Voltage (nom.) | 28±0,2 Vdc |
36±0,2 Vdc | |
12±0,2 Vdc | |
24±0,2 Vdc | |
5±0,2 Vdc | |
Output Current (max.) | 20±2 A ( upto 75% between +55 °C +63 °C operation temperature) |
Output Power (nom.) | 2000W |
Environmental Features
Operating Temperature | -30ºC ~ +55ºC |
Storage Temperature | −40ºC~ +70ºC |
Humidity | %95 (+40ºC’ de ) |
Mechanical Features
Width | 482±1 mm, |
Height | 43±1 mm (1U), |
Depth | 575±1 mm |
Cooling | Built in Axial Fan |
Weight | 13±0,2 kg |
Compliance with Standards
Compliance with Standards | MIL-STD-810E-G: Environmental Conditions Compliance |
MIL-STD-461G: Electromagnetic Compliance | |
MIL-STD-1275B: Electrical Compliance for Military Grade Vehicles | |
MIL-STD-1399 300B: Military Grade Alternative Current Compliance | |
STANAG 1008 ve MIL-STD-1399 300B | |
MIL-STD-461D (ship and submarine) | |
CE101, CE102, RE101, RE102, RE103, CS101, CS114, CS116 |
Other Features
Other Features | In case of power failure in the AC supply line, the unit automatically and uninterruptedly provides an uninterrupted transition to the DC supply line. |
With the RS422 Communication Infrastructure, it can communicate with the units connected to the unit that this infrastructure. | |
3600W output power option | |
MTBF: 15000 hour | |
MTTR <30 min | |
Life Time: min 40000 hour |