U
PLAYS WITH POWER

Search the Web

ELS-2K0-PSU-V1

2000W AC/DC POWER SUPPLY and POWER DISTRIBUTION UNIT

GENERAL INFORMATION

The 2000W Power Supply and Power Distribution Unit is capable of operating with
both AC and DC voltage.

In case of power failure in the AC input line, the unit automatically and mains
provides a seamless transition to the DC input line.

It generates Multiple DC power at different voltage and current levels from AC or DC source.

With the RS422 Communication Infrastructure, it can communicate with the units
connected to the unit and having this infrastructure.

TECHNICAL FEATURES

Input Features
AC Input Voltage Range
100-265Vac (Nominal 220Vac, Phase-Neutral)
Input Frequency Range
47-63Hz
Efficiency at Full Load
>92 at Nominal Input
Power Factor at Full Load
>95%(typically %99)
Current Total Harmonic Distortion
<%5
Instantaneous Input Current Opening Value
<50A except for the first 10ms
Leakage Current Value to the Body
<30mA
DC Input Voltage Range
20-30 Vdc (Nominal 24Vdc)
Input Isolation
DC input line is isolated from chasis
Output Features
Output Voltage (nom.)
28±0,2 Vdc
36±0,2 Vdc
12±0,2 Vdc
24±0,2 Vdc
5±0,2 Vdc
Output Current (max.)
20±2 A ( upto 75% between +55 °C +63 °C operation temperature)
Output Power (nom.)
2000W
Environmental Features
Operating Temperature
-30ºC ~ +55ºC
Storage Temperature
−40ºC~ +70ºC
Humidity
%95 (+40ºC’ de )
Mechanical Features
Width
 482±1 mm,
Height
43±1 mm (1U),
Depth
575±1 mm
Cooling
Built in Axial Fan
Weight
13±0,2 kg
Compliance with Standards
Compliance with Standards
MIL-STD-810E-G: Environmental Conditions Compliance
MIL-STD-461G: Electromagnetic Compliance
MIL-STD-1275B: Electrical Compliance for Military Grade Vehicles
MIL-STD-1399 300B: Military Grade Alternative Current Compliance
STANAG 1008 ve MIL-STD-1399 300B
MIL-STD-461D (ship and submarine)
CE101, CE102, RE101, RE102, RE103, CS101, CS114, CS116
Other Features
Other Features
In case of power failure in the AC supply line, the unit automatically and uninterruptedly provides an uninterrupted transition to the DC supply line.
With the RS422 Communication Infrastructure, it can communicate with the units connected to the unit that this infrastructure.
3600W output power option
MTBF: 15000 hour
MTTR <30 min
Life Time: min 40000 hour