U
PLAYS WITH POWER

Search the Web

ELS-1K7-CHR-V5

1700W BATTERY CHARGER

GENERAL INFORMATION

1700W power supply and battery charger specially designed for multi-barreled rocket launching weapon systems and air defense missile systems vehicles developed by ROKETSAN.

It is suitable for use on land platforms, in vehicles and shelters. It works with 176-265 Vac input voltage.

The rated output voltage is 28Vdc, the output power is 1700W, it works with at least 90% efficiency at full load. Its weight is only 5kg.

TECHNICAL FEATURES

Input Features

 

AC Input Voltage Range
176-265 VAC
Input Frequency Range
47-63 Hz
Input Power Factor
>0,99 (at 220 VAC input & full load)
Input Current THD
<%3
Power Dissipation without Load
<80 W
Input Leakage Current
<3,5 mA (IEC 60950 uyarınca)
Output Features
Output Voltage (nom.)
28,2±0,4 VDC
Input Current (max)
60A
Output Power (nom.)
1700 W
Output Voltage Fluctuation
20 MHz band with <300 mVp-p
Output Voltage Surge
20 MHz band width <600 mVp-p
Efficiency
>%90 (220 VAC input voltagebetween 50% to 100% linear load)
Environmental Features

 

Operating Temperature
−32°C ~ +50°C
Storage Temperature
−40°C ~ +60 °C
Acoustic Noise
<55 dB(A) (1 m distance)
Mechnical Features
Dimensions
Width: 202mm,
Height: 87 mm,
Depth: 446 mm
Cooling
Built in axial fan, rear to back
Weight
5±0,2 kg
Compliance to Standards
Compliance to Standards
MIL-STD-810F Metot 516.5
MIL-STD-810E: Compliance to Environmental Conditions
MIL-STD-461E: Electromagnetic Compatibility
MIL-STD-1275E: Electrical Compliance for Military Grade Vehicles
MIL-STD-461G
CE101, CE102, RE101, RE102, CS114, CS115, CS116
Other Features
Other Features
Parallel connection and load sharing of up to 4 units
Input undervoltage and overvoltage protection
Input overcurrent protection
Battery reverse connection protection on output
Output undervoltage and overvoltage protection
Protection against overload and short circuit at the output (hiccup)
Output overcurrent protection (Max.: 10% more than rated current)
Preventing battery discharge when unit is off