BC2014

TECHNICAL SPECIFICATIONS

Input Specifications

DC INPUT

  • Input Voltage Range:
    10,5-36 VDC
  • Input Compatibility:
    MIL-STD-1275D/E
  • Input Protection:
    Electronic shut-down when input voltage is out of operation limits
  • Input Reverse Connection Protection:
    Uninterruption up to 36 VDC

AC INPUT

  • Input Voltage Range:
    90-265 VAC & 47-63Hz

DC Output Specifications

  • Maximum Output Power:
    300W
  • Output Channels:
    Independent 4 Channel, Max. 6A per channel
  • Output Protection:
    Over power protection and short circuit protection for limitless time.
    Automatic recovery.

Environmental Characteristics

  • Operating Temperature
    MIL-STD-810F, Method 502.5, Procedure II, -30°C
    MIL-STD-810F, Method 501.5, Procedure II, +50°C
  • Storage Temperature:
    MIL-STD-810F, Method 502.5, Procedure I, -30°C,
    MIL-STD-810F, Method 501.5, Procedure I, +60°C
  • Vibration
    MIL-STD-810G, Method 514.5, Procedure I & III, Category 20
  • Mechanical Shock
    MIL-STD-810G, Method 516.6, Procedure I. Functional Shock 20G,
    11ms, saw teeth in opposite directions on all axes
  • Relative Humidity
    up to 95% (non-condensing)
  • Rain
    MIL-STD-810G, Method 506.5, Procedure I (when the unit cover closed)
  • Sand and Dust
    MIL-STD-810G, Method 510.5, (when the unit cover closed)

Mechanical Characteristics

  • Weight :
    Approx. 3.3 Kg
  • Package type:
    IP67; GRP / Leakproof (when the unit cover closed)
  • Cooling:
    Forced air cooling with internal fan
  • Dimensions: Width : 275 mm
    Height : 125 mm
    Depth : 250 mm
  • Material / Colour
    Polypropylene / Desert Tan
  • Support Bracket for Mounting Plate

EMC/EMI CAPABILITY

  • MIL-STD-1275D
    IES Test, Conducted Susceptibility
    Distortion in the power line
  • MIL-STD-1275E
    Voltage Ripple Test, Conducted Susceptibility, Power Line, 30Hz-250kHz
  • MIL-STD-1275E
    Voltage Spike Test, Conducted Susceptibility,
    Instant signal in the power line
  • MIL-STD-1275E
    Voltage Surge Test, Conducted Susceptibility,
    Surge in the power line
  • MIL-STD-461E
    CE102 Test, Conducted Emission, Power Lines, 10kHz-10MHz

Aksesuarlar