Naval Military Grade 1500 VA DC / AC Inverter

19” Rack, Pure Sine-Wave “24 Vdc” Input “220 Vac / 50 Hz” Output

Especially suitable for “Naval” use, 19” Rack Type, with “IP-67” protection class. Made to comply with stringent Naval Military Specifications for Choke, Vibration, Temperature, Salt Mist, EMI/RFI and Electrical Transients. Unit is cooled by 24 Vdc water-proof fans.

ELSIS Co. Inc. established in 1971 is a “ISO-9001” certified company by accredited “KEMA” since 1999.

Main Technical Specifications of “28 Vdc / 220 Vac - 50 Hz” Inverter:

ModelELSIS / “ELS-1K0-INV-V2” ; “ELS-1K5-INV-V2” ;
“ELS-2K0-INV-V1”
ManufacturerELSİS A.S.
Output Power1000 / 1500 / 2000 VA; (under linear load)
Input Voltage Range20 – 33 Vdc
Ripple Reflected to InputLess than 200 mV rms
DC Input CompatibilityMIL-STD-1275B; (Bat. only, Gen. only, Bat.+ Gen.)
Noise Reflected to InputLess than 500 mV (pp) under full load
No-Load Power DissipationLess than 80 W
Input ProtectionElectronic shut-off when input voltage is out of operation range, and effective fuse protection against reverse battery connection.
Output Voltage Stability220 Vac; +/-1% (can be tailored to customer request)
Output Frequency and Stability50 Hz; +/-0,5% (can be tailored to customer request)
Load Power FactorFull capacitive, resistive to full inductive
Output Wave FormSinusoidal
Output THDBetter than 3%
Crest FactorBetter than 3:1
Allowable Over-LoadUp to 2500 VA, for 2 seconds (the 1500 VA unit)
DC Content On OutputLess than 100 mV
Output Protection and Current LimitingFull and continuous electronic protection against over-load and short-circuit (current limiting without distorting the output wave form); optional Thermal-Magnetic circuit-breaker may be added
EfficiencyAbove 87% under 50% to 100% linear load
Electromagnetic Compatibility“MIL-STD-461F”: CE101; CE102; RE101; RE102; CS101; CS106; CS114; CS115; CS116; RS101; RS103
Duration of OperationContinuous, 24 hours a day, 7 days a week
Weight23 kg (apprx. 50 lb)
CoolingForced air cooling by waterproof 24Vdc axial fans
Mechanical UnitsMetric (can be modified to customer request)
DimensionsW: 184 mm; H: 130 mm; D: 400 mm (Less handle bar & connectors)
Front Panel Controls, Indicators and Rear Panel ConnectionsPower On/Off switch, Power On LED, Fault “LED”, on the front panel; “MS-3102” circular connectors, T/M circuit breakers, and passive fuse sealed cover
Operation Ambient TemperatureBetween -32o C and +55o C
Storage Ambient TemperatureBetween –40o C and +70o C
Salt and MistMIL-STD-810F Method 509.4
Mechanical ChokeVertical, half sine wave, 64g for 6 ms and 32g in other directions
VibrationMIL-STD-810F 514.5-I; 514.5C-16 Methods and MIL-STD 1399 Sec 301A ship movements
Acoustical NoiseLess than 45 dB(A)
Operation Altitude4000 m; above 4000 m according to degradation curve
Relative HumidityMIL-STD 810F; 507.4