| Brand / Model | ELSİS; “ELS-0K4-INV” |
| Manufacturer | ELSİS A.S. |
| Output Power | 500 VA / 400 W (under linear load) |
| Input Voltage Range | 18 – 33 Vdc |
| Ripple Reflected to Input | Less than 200 mV rms |
| DC Input Compatibility | MIL-STD-1275B |
| Noise Reflected to Input | Less than 500 mV (pp) under full load |
| No-Load Power Dissipation | Less than 35 W |
| Input Protection | Electronic shut-off when input voltage is out of operation range and effective fuse protection against reverse battery connection |
| Output Voltage Stability | 115 Vac; +/-1% (can be tailored to customer request) |
| Output Frequency and Stability | 60 Hz; +/-0,5% (can be tailored to customer request) |
| Output Power Factor | 0,8 |
| Output Wave Form | Sinusoidal |
| Output THD | Better than 3% |
| Crest Factor | Higher than 3:1 |
| Allowable Over-Load | Up to 750 VA, for 2 seconds |
| DC Content On Output | Less than 100 mV |
| Output Protection and Current Limiting | Full and continuous electronic protection against over-load and short-circuit (current limiting without distorting the output wave form); in addition Thermal-Magnetic circuit-breaker |
| Efficiency | Above 80% under 50% to 100% linear load |
| Electromagnetic Compatibility | MIL-STD-461F, CE101, CE102, RE101, RE102, CS101, CS106, CS114, CS115,CS116, RS101, RS103 |
| Static “By-Pass” | Normally load is on external source when voltage is within allowed limits; otherwise automatically transferred to Inverter output |
| Duration of Operation | Continuous, 24 hours a day, 7 days a week |
| Weight | 11 kg (apprx. 20 lb) |
| Cooling | Natural convection cooling |
| Mechanical Units | Metric (can be modified to customer request) |
| Dimensions | W: 430 mm; H: 80 mm; D: 365 mm |
| Front Panel Controls, Indicators and Rear Panel Connections | Separate T/M Switches for AC and DC Inputs; similar switch for AC Output, “LED” indicators on the front; “MS-3102” circular connectors and passive fuse on the rear panel |
| Operation Ambient Temperature | Between -32o C and +55o C |
| Storage Ambient Temperature | Between –40o C and +80o C |
| Salt and Mist | MIL-STD-810E Method 509.3, 48 hours mist and 48 hours dry time |
| Mechanical Choke | MIL-STD-810E |
| Vibration | MIL-STD-810E, Category 8, Military Land Vehicle |
| Acoustical Noise | Less than 50 dB(A) |
| Operation Altitude | 2000 m; above 2000 m according to degradation curve |
| Relative Humidity | Up to 90% (without condensation) |