| Brand / Model | ELSİS; “ELS-K07-INV-V1” |
| Manufacturer | ELSİS A.S. |
| Output Power | 50VA - 100VA |
| Input Voltage Range | 18 – 36 Vdc |
| Ripple Reflected to Input | Less than 300 mV rms |
| DC Input Compatibility | MIL-STD-1275B |
| Noise Reflected to Input | Less than 100 mV (pp) under full load |
| No-Load Power Dissipation | Less than 10 W |
| Input Protection | Electronic shut-off when input voltage is out of operation range |
| Input Reverse Polarity Protection | Up to 50Vdc continuous |
| Line Regulation | +/-2% |
| Load Regulation | +/-2% |
| Output Frequency Stability | +/-0.1% Hz |
| Output Power Factor | Full capacitive, resistive to full inductive |
| Output Wave Form | Sinusoidal |
| Output THD | Better than 3% |
| Crest Factor | Better than 3:1 |
| Allowable Over-Load | %20 Temperature Limited |
| DC Content On Output | “0” V |
| Out-Put Protection and Current Limiting | Continuous electronic protection for unlimited time against over-load and short-circuit , Auto recovery |
| Efficiency | 70 to 78% from 40% load |
| EMI/RFI | Designed to meet requirements of MIL-STD-461E |
| Environmental Conditions | Meets or exceeds the requirements of MIL-STD-810E |
| Duration of Operation | Continuous, 24 hours a day, 7 days a week |
| Weight | 524g (apprx. 1.15 lb) |
| Cooling | Conduction cooling, assembled on a base plate not to exceed 90°C |
| Mechanical Units | Metric (can be modified to customer request) |
| Dimensions | W: 87.5 mm; H: 34 mm; D: 87.5 |
| Package Type | Not Encapsulated |
| Front Panel Indicator | Output “OK” indicator Green LED |
| Front Panel Connector with Special Features | DB15
Remote supervising signal isolated output |
| Operation Ambient Temperature | Between -40o C and +90o C (Base-plate) |
| Storage Ambient Temperature | Between –55o C and +125o C |
| Salt and Mist | MIL-STD-810F Method 509.4 |
| Mechanical Choke | MIL-STD-810F, Method 516.5, Procedure 1- Functional Choke 40g, 11 ms, saw tooth on all axes, opposite directions, Military Land Vehicle |
| Vibration | MIL-STD-810F, Category 24, Procedure-1 (Annex A 2.4.1) minimum integrity on all axes, 1 hour each |
| Relative Humidity | Up to 90% (without condensation) |
| Isolation | 200V Between output and input (26 Vac rms)
500V Between output and input (115 Vac rms)
100V Between output and case |